-
Gas flux (EC1)
Eddy covariance flux measurements started in 2012. The mast (2 m high) is located about 100 m east of Arctic Station in a moist tundra site called Ãsterlien. It is a gentle... -
Sentinel-3 Chlorophyll-a Estimates - Disko, Nuuk and Zackenberg
Sentinel-3 daily aggregated and outlier masked Chlorophyll-a estimates for Disko, Kobbefjord and Zackenberg GEM Stations. Sentinel-3 OLCI level 2 data, operationally processed... -
Remote sensing land surface temperature (LST) - data
See https://github.com/KU-AVOCA/GEMLST for detailed description of the data -
Land surface temperature tools
GEM remote sensing land surface temperature tools on google earth engine have been developed to explore both timeseries and daily maps of Greenland wide land surface... -
cloud cover map every 10 minutes.
Cloud cover map obtained by classifying image pixels from a hemispheric optical camera as cloudy or clear and projecting the pixel coordinates into geographical space. The... -
soil temperature 1.3 m - 60 min sample
Soil temperature measured at 1.3 m depth using Campbell Scientific 107-L temperature probe. Data comments: : 2004-2006: Data deleted or suspect due to high frequency... -
soil temperature 1.0 m - 60 min sample
Soil temperature measured at 1.0 m depth using Campbell Scientific 107-L temperature probe. Data comments: Data comments: 2004-2006: Data deleted due to broken sensor. August... -
soil temperature 0.8 m - 60 min sample
Soil temperature measured at 0.8 m depth using Campbell Scientific 107-L temperature probe. Data comments: : 2004-2006: Data deleted or suspect due to high frequency... -
soil temperature 0.6 m - 60 min sample
Soil temperature measured at 0.6 m depth using Campbell Scientific 107-L temperature probe. Data comments: 2004-2006: Data deleted or suspect due to high frequency fluctuations... -
soil temperature 0.4 m - 60 min sample
Soil temperature measured at 0.4 m depth using Campbell Scientific 107-L temperature probe. Data comments: 2005-2006: Data deleted due to unstable battery charge and high... -
soil temperature 0.2 m - 60 min sample
Soil temperature measured at 0.2 m depth using Campbell Scientific 107-L temperature probe. Data comments: 2004-2006: Data deleted or suspect due to high frequency fluctuations... -
soil temperature 0.1 m - 60 min sample
Soil temperature measured at 0.1 m depth using Campbell Scientific 107-L temperature probe.Data comments: 2004-2006: Data deleted or suspect due to high frequency fluctuations... -
River Discharge
River discharge measured with continuous water level measurements converted by a stage-discharge relation based on manual discharge measurements. 15 min sample values in m3/s.... -
snow depth - 180 min
Snow depth measured by an ultrasonic ranger. Given is an average over the last 3 minutes of every 3rd hour. Data is primarily based on the sensor attached to station 641 and... -
Snow pit temperature - manual measurement (°C)
Snow pit temperatures observed at the annual snow surveys taking place in the end of the snow season in late winter (app. April). The logging consists of snow temperature... -
Snow pit stratigraphy - manual measurement
Snow pit stratigraphy observed at the annual snow surveys taking place in the end of the snow season in late winter (app. April). Logging of the stratigraphy includes... -
Snow pit density - manual measurement (kg m-3)
Snow pit densities observed at the annual snow surveys taking place in the end of the snow season in late winter (app. April). The logging consists of density measurements taken... -
River Discharge (Teqinngalip)
River discharge measured with continuous water level measurements converted by a stage-discharge relation based on manual discharge measurements. 15 min sample values in m3/s.... -
River Discharge (Oriartorfik)
River discharge measured with continuous water level measurements converted by a stage-discharge relation based on manual discharge measurements. 15 min sample values in m3/s.... -
River Discharge (Langesø)
River discharge measured with continuous water level measurements converted by a stage-discharge relation based on manual discharge measurements. 60 min sample values in m3/s....